Installation method of hydrophilic PTFE Membrane Filter Cartridges

date:2020-6-15 19:4:42   Number of times:

1. Wet the O-ring and slowly insert the filter cartridge vertically, all of which must be inserted into the stainless steel groove.
2. Press the fin of the filter element with a stainless steel orifice plate so that the pressure plate does not need to be too tight to prevent the filter cartridge from being deformed during high temperature disinfection.
3. Avoid touching the filter cartridge directly by hand.
4. Rinse the filter cartridge as much as possible before use.
5. Please turn the valve slowly and do not open or close it all at once when turning on or off, so as to prevent the filter from being sucked up during high temperature disinfection.

Maintenance method of hydrophilic PTFE Membrane Filter Cartridges

When the filter element can not meet the design flow (the pressure gauge difference decreases obviously in 0.1MPa), please stop the machine and open the filter housing, remove the filter cartridge, rinse the stolen goods on the surface with clean water, soak in 4% hydrochloric acid for 24 hours, then soak in 4% sodium hydroxide for 24 hours as well, at last, rinse with clean water (remove two O-rings when soaking to prevent expansion).

Hydrophilic PTFE Membrane Filter Cartridges storage method:

1. Soak the filter cartridge in the disinfectant and fill the stainless steel shell of the filter with disinfectant.
2. Take out the filter cartridge and dry it (50 hours after drying).
3. Take out the filter cartridge to dry in the dry climate area.
4. Please do not pack the undried filter cartridges in plastic bags to prevent mildew.